A certified radio module, and still not done: the cybersecurity requirements of the RED
Since 1 August 2025, the Radio Equipment Directive has set cybersecurity requirements for equipment with a radio. What that means in engineering terms, and how it connects to the CRA.
Imagine your new machine gets a 4G gateway for remote service. The team picks a radio module with a CE marking and its own declaration of conformity. The radio part seems done. Then a customer asks at handover for your declaration covering the cybersecurity requirements of the Radio Equipment Directive.
Since 1 August 2025, the RED (Directive 2014/53/EU), through Delegated Regulation (EU) 2022/30, has set cybersecurity requirements for radio equipment that can communicate over the internet, directly or via other equipment. Those requirements cover the whole product, not just the radio. And whoever places the product on the market under their own name is the manufacturer. That is you.
The module is not the product
A certified radio module does not take care of your machine's cybersecurity. Module manufacturers' own application notes point this out too: the end-product manufacturer carries out its own conformity assessment. The reason is technical. Whether there is a default password, how an update is verified, where keys are stored and which services are exposed is decided by your firmware and your cloud, not by the module.
A 4G or WiFi gateway that speaks IP clearly communicates over the internet. For a Bluetooth service interface there is no consensus. Assess that per product and record your reasoning in the risk assessment.
Three requirements in engineering terms
Article 3(3) of the RED has three cybersecurity parts:
- (d) Do not harm the network. No defaults that make the device easy prey for a botnet, only the services that are needed, and secure updates.
- (e) Protect personal data and privacy. If the device processes personal, traffic or location data, such as operator logins. Think of access control, encryption and deleting data.
- (f) Protect against fraud. Only if the device transfers money or monetary value.
EN 18031 and the password trap
Since January 2025, the harmonised standards EN 18031-1, -2 and -3 have been cited, one for each requirement, in Implementing Decision (EU) 2025/138. They describe mechanisms an embedded engineer will recognise: access control, authentication, secure updates, secure storage, secure communication and keys without static default values.
The European Commission cited the standards with restrictions. The one that matters most for machine builders: if the user is allowed to skip setting a password, the standard gives no presumption of conformity. If you hit a restriction, you have applied the standard only in part. Self-assessment is then no longer possible: you need a notified body, with its lead time.
So a setup wizard with a "set up later" button can make the difference between declaring conformity yourself and an external assessment. Make that design decision early.
From RED to CRA
On 11 December 2027 these RED rules are repealed by Delegated Regulation (EU) 2026/339, and the Cyber Resilience Act takes over for radio equipment placed on the market from that date. This applies per unit, not per type. A machine you deliver between 1 August 2025 and 10 December 2027 remains subject to RED market surveillance after that date.
The CRA requirements include everything the RED asks for here, and add obligations for the whole product life: vulnerability handling, an SBOM, a support period with security updates and the reporting obligation. Reporting has applied since 11 September 2026, even to products already on the market.
EN 18031 gives no presumption of conformity under the CRA. How much of your RED evidence can be reused in a CRA technical file is something to check per product. The engineering underneath is the same, though: secure boot, signed updates, key management and a small attack surface. Build it properly now and it serves both.
Five steps for your next machine
- Map every radio interface and data path: WiFi, 4G, Bluetooth, LoRa, and the route through gateway, app and cloud. For each, decide in writing whether it reaches the internet and which requirements apply.
- Check the restrictions early. Enforce a password or unique credentials. If you do hit a restriction, plan for a notified body.
- Close the update chain: secure boot, signed images, anti-rollback and a recovery path. See Secure boot and secure updates on embedded Linux.
- Reduce the attack surface: close debug and service ports in production, authenticate local interfaces, drop unused services.
- Build the technical file: risk assessment, applicability decisions, test reports and an EU declaration of conformity that lists Article 3(3) and EN 18031.
Read more in The CRA explained for machines and devices. Where does your product stand? Take the free CRA check, or have the platform technically assessed with the CRA quick scan. Formal assessment is done by a notified body or test lab. This article is general information, not legal advice.
A radio in your product?
The CRA quick scan assesses secure boot, updates, access and keys: the engineering under both the RED and the CRA.